open

FLUX_MODEL is not zero in areas where measurement weights are 0

Added by Emmanuel Bertin over 8 years ago. Updated over 8 years ago.

Status:
Resolved
Priority:
Normal
Start date:
09/11/2013
Due date:
09/25/2013 (over 8 years late)
% Done:

0%

Estimated time:
(Total: 0.00 h)
Spent time:

Description

This happens in double image mode (thanks to Eli Rykoff for finding out).


Subtasks

Actions #1

Updated by Emmanuel Bertin over 8 years ago

measurement scalars and vectors need to be reset between analysis runs on detections.

Actions #2

Updated by Emmanuel Bertin over 8 years ago

  • Status changed from New to Resolved

Added missing reset of measurements parameters (zerocat() function) at each catalog initialization in v2.19.3 (revisions r320 and r321)